In plain terms
The UK's fast-response grid support services need a generator to react within seconds, at any moment over a 4-hour period. A ground receiving station on its own could not promise that, so it would need its own battery to offer this kind of service.
The claim as recorded
GB frequency-response ancillary services are contracted over 4-hour windows requiring the supplier to respond within seconds if called upon, and the report concludes that a rectenna could not deliver these services unless co-located with a battery able to guarantee delivery at any point in the 4-hour window.
Scope and limits
This is Frazer-Nash's own analytical conclusion for the GB market and this specific reference design, not a demonstrated technical limit of rectenna hardware in general, and does not address ancillary-market rules outside Great Britain.
What it assumes
The rectenna's power output cannot itself be modulated on second timescales independent of the incoming beam; a co-located battery is the only route to meeting the response-time requirement.
Where it comes from
p.34: "Frequency response services are contracted over 4-hour windows (electricity forward agreement (EFA) blocks), during which the supplier must be available to respond (on timescales of seconds or less) if required. For this reason, delivery of these services would only be possible if the rectenna were co-located with a battery that could ensure delivery at any time within the EFA block." Confirmed verbatim against the PDF text layer.
Basis: Great Britain ancillary-services market rules (frequency response, EFA blocks)
Related records
- Answers question
- QST-002 not published in this release
Cite this
energyaperture.com/c/clm-0216
CLM-0216, Energy Aperture, as of 2025.
Connected records
Other published records linked to this one. A list, not a judgement.
- Also from SRC-076
- CLM-0018The most recent UK government report calls 230 watts per square metre a limit to be reached because it lowers cost, and cites an earlier...CLM-0019The report sets out Space Solar's plan: a small in-orbit test, then 31 megawatts in 2030, 150 megawatts in 2033, and 650 megawatts in...CLM-0152Two UK industry planning documents, from 2022 and 2025, each state a beam-intensity design figure in the 230-245 watts-per-square-metre...CLM-0213The study assumes that connecting a ground receiving site to the electricity grid costs about GBP 150,000 for every megawatt of power the...CLM-0214Six different solar-power-satellite designs each claim that turning the electricity collected on the ground into grid-ready power is 90 to...CLM-0215Any UK ground receiving station that wants to connect to the electricity grid must be able to supply or absorb a type of power called...CLM-0503Under the international radio rules as revised at the 2023 world radio conference, there is no radio-frequency allocation for beaming power...CLM-0517Every date in the plan -- the ground demo (2026), the demo mission (2027-28), 2030, 2033 and 2036 -- is a hope, not a booking, and the...More on the source page.