Energy Aperture

CALC-065

Discount rate as a mechanical lever, and the direction it runs

Calculation · Cited by CLM-0380 , CLM-0386 , CLM-0389 , CLM-0390 , CLM-0523 , CLM-0525

What this is

This is the project's own arithmetic, published in full so it can be checked rather than taken on trust. It is not a source. Every input it uses is cited to a record, and the conclusion it reaches only carries as far as those inputs do.

Feeds CLM-0380 and CLM-0523. SHARED - two claims, one section. Answers QST-004. Basis: dimensionless CRF ratios.

Script. restate-lcoe.py SECTION 7, section_decomposition() sub-heading (b), emitted at line 692. Note the locator: CLM-0380's `src` says Section 4(b) and its `support` says Section 7(b). The `support` field is right.

Why it was needed. Discount rate was the leading candidate explanation for the spread before the exercise ran - it is the largest single lever in most LCOE comparisons. Establishing its size was necessary; establishing its direction is what actually settled the question.

Inputs.

QuantityValueSourceStated or assumed
Frazer-Nash native hurdle rate20 per centSRC-021, SRC-078STATED
NASA native discount rate3 per centSRC-012 p.56STATED
Caltech native discount rate2 per centSRC-006 (Mizrahi et al. 2025, Joule)STATED
Native asset life for the lever comparison30 yr, heldboth studiesSTATED

All four inputs are STATED by their sources. There is no assumed parameter in this record, which is why it carries a mechanism finding at MED confidence on arithmetic alone.

Working, transcribed.

CRF( 2 per cent, 30 yr)  =  0.04465
CRF( 3 per cent, 30 yr)  =  0.05102
CRF(10 per cent, 30 yr)  =  0.10608
CRF(20 per cent, 30 yr)  =  0.20085

CRF(20%,30yr) / CRF(2%,30yr)  =  4.5 x
CRF(20%,30yr) / CRF(3%,30yr)  =  3.9 x

Result: 3.9x to 4.5x, the largest single mechanical lever measured in isolation in this corpus.

Conclusion, and the direction is the entire finding. The study with the lowest raw LCOE (Frazer-Nash) carries the highest discount rate, 20 per cent. The study with the highest raw LCOE (NASA) carries the lowest, 3 per cent. Equalising the rate therefore moves the two apart, not together. A 4x lever pointed the wrong way does not explain a 20x gap; it deepens it. This is the quantitative confirmation of what CLM-0360's notes had already recorded qualitatively.

Where this fails. A description of the pattern in this corpus's two institutional anchors. It is not a general claim that discount rate never explains cost differences between studies - only that it does not explain this one. CLM-0380's own limits field says exactly that and it should travel with the record.

Why CLM-0523 needs no separate record. Its support field reads, in full, "Reproduced from CLM-0380 in full." Same CRF values, same 3.9-4.5x, same direction argument. It exists to serve a different document's Pillar 4 and adds no arithmetic. Drafting a second record would be drafting the same four CRF values twice.

Cite this

energyaperture.com/calc/calc-065

CALC-065. The working above, not a source document.