Does ICNIRP's averaging reduce the design figure?
What this is
This is the project's own arithmetic, published in full so it can be checked rather than taken on trust. It is not a source. Every input it uses is cited to a record, and the conclusion it reaches only carries as far as those inputs do.
Feeds CLM-0009. This is the step that decides QST-001, so it is the one most in need of challenge.
The question. ICNIRP Table 5 reference levels are "averaged over 30 min and the whole body". An averaged limit can be met by a source whose instantaneous or local peak is far higher. Does that apply here?
Time averaging. The limit averages over 30 minutes. A power satellite beams continuously under normal operation, so over any 30-minute window the time-averaged incident power density equals the instantaneous value. No reduction.
Spatial averaging. The limit averages over the whole body, so a reduction requires the incident power density to vary substantially across a human body.
Rectenna major axis: 13 km = 1.3e4 m
Human body height scale: ~1.8 m
Ratio: 1.3e4 / 1.8 = ~7.2e3The illuminated region is roughly four orders of magnitude larger than a body. A beam profile that varies smoothly over kilometres is effectively uniform over 1.8 m, so the whole-body spatial average equals the local value. No meaningful reduction.
Result: the averaging conditions do not reduce the design figure. The comparison between the 230-245 W/m2 design peak and the 10 W/m2 reference level is therefore valid at the beam centre.
Where this fails, stated plainly. Two assumptions carry it, and neither is sourced:
1. The beam is continuous. If it were pulsed or duty-cycled, the 30-minute average would fall in proportion to the duty cycle. None of the five documents reviewed states a duty cycle. 2. The profile varies over kilometres, not metres. If the design used fine spatial structure - an interference pattern with metre-scale nulls, say - the whole-body average could be well below the peak. Nothing reviewed suggests this, but nothing rules it out either.
Both assumptions must be tested against a source before this calculation supports anything public. A verifier should attack these two points first.