The programme's own sizing arithmetic, with its rate of return stated: in the cases studied a bigger antenna always raised the cost, but much less if the ionospheric limit rose with it. The 152.3 in its cost formula is the capital-recovery factor for 15 per cent over thirty years.

The claim as recorded

NASA's 1980 sizing paper states the closed-form relationships between transmit antenna area, peak array power density, transmitted power and peak ground power density for a Gaussian taper, sizes the rectenna to capture 88 per cent, and costs each configuration at "a 15-percent rate of return on investment capital", "0.92 plant factor" and a 30-year life through the formula mills/kWh = 152.3 x system cost ($ million) / (8,050 x GW); the reference system is 59,984 t and $12,432 million at 47 mills/kWh, and enlarging the antenna to 1.36 to 2 km under a fixed 23 mW/cm2 limit raises electricity cost by 52 to 283 per cent, while the same antennas with the limit raised to 42 to 91 mW/cm2 raise it by only 11 to 43 per cent.

Evidence behind this: T3-programme office technical paper; equations stated in closed form and a costing basis stated.

Scope and limits

1977-DOLLAR COSTS BY SCALING FACTORS FROM THE BOEING REFERENCE (TABLE B-1), NOT RE-ESTIMATED; the paper's stated purpose is differential, not absolute, cost. Table 1 gives 2.72 GW for the 1.36 km case where Table 3 prints 2.7 and the conclusions page (printed 21) gives 2.76.

What it assumes

No assumptions are recorded against this claim.

Where it comes from

SRC-556 Solar Power Satellite System Sizing Tradeoffs; NASA Technical Paper 1804; February 1981, 1981
PDF p.9, equations (1) and (2) from the render, which reproduce 6.76 GW against the reference 6.72 only at a peak array power density PD-ARRAY of 22 kW/m2, a value TP-1804 does not state: its printed 5 gives the thermal limit as 23 kW/m2, which puts equation (2) at 7.07 GW, and its Table 1 gives the reference's transmitted power as 6.5 GW. PDF p.14, raw: "15-percent rate of return on investment capital", "0.92 plant factor", "30-year". PDF p.15, raw: "59 984" metric tons and "$12 432" million. PDF p.31, raw: "152.3", "8050". Table 3, PDF p.16, from the render, raw "47". Arithmetic: CRF(15 per cent, 30 years) = 0.1523, so 152.3 is that factor times 1,000; 8,050 is 8,750 hours x 0.92 plant factor exactly, not 8,760 rounded (the page's 7,875 is 8,750 x 0.90).

Basis: mills/kWh at a 15 per cent rate of return, 0.92 plant factor, 30 years; 1977 USD

Related records
Answers question
QST-037 not published in this release

Cite this

energyaperture.com/c/clm-1036

CLM-1036, Energy Aperture, as of 1980-12.